HFC Headend
AIMA3000 - Return Receivers

AIMA-RRAS

Analog Return Receiver - Standard
AIMA-RRAS

The PBN AIMA3000 RRAS series Analog Return Receiver – Standard is designed for multi-services operators to increase network-return capacities for the ever-growing demand for bandwidth, while minimizing physical headend space and power usage.

With the optional embedded Full Band Capture (FBC) module, it enables the operator to capture and monitor the return path spectrum helping the operator to quickly find and locate the upstream noise and the related upstream signal levels. Advanced spectrum analyzing software is available as in a standalone version or as module within PBN’s NMSE Software suite. It also can be easily integrated into operators exist network management system.

Next to above mentioned online management and controling capabilities the can also be conveniently monitored and controlled through a computer directly connected to one of the Ethernet ports of the ASMM module.

All module settings are retained in non-volatile memory to ensure trouble-free operation. Bulk updating, automatic uploading and downloading of configuration files is possible using PBN’s NMSE web-based management system.


Bandwidth 5 ~ 204 MHz to meet EuroDOCSIS and DOCSIS3.0/3.1 frequency band requirements


RF output 47.5 dBmV at -6 dBm optical input and OMI of 6%


Wide band receiver (1260 ~ 1620nm) to suit CWDM and DWDM applications


Allows up to 64 receivers (4x16 Modules) in only 4 RU of space


User-selectable MGC or AGC


Easy to install due to RF-Paddle board backplane design


Plug-and-play and hot-swappable


Dedicated testport per return channel



Fully FCC, CE and RCM compliant


Real-time alarm monitoring with supported SNMP traps, and local alarm management through the ASMM


Full Band Capture offers automated and 7*24 return path/upstream RF and data performance monitoring and analysis


Assist operators to preemptively identify and address spectrum variances


Lower capital expenses by eliminating the need for expensive test equipment


Web-browser access eliminates the need for a thick client. A mobile APP is also available for field technicians to remotely access spectrum data


An intuitive and familiar user interface, designed with spectrum analyser operators in mind


Improve network maintenance efficiency and Increase customer satisfaction


FBC software which can work independently, in PBN NMSE or be integrated into third-party systems


Optical Performance
Optical wavelength 1260 nm to 1620 nm
Optical inputs -18 dBm to +2 dBm
Optical return loss > 50 dB
Optical connector 4 x SC/APC (1) , FC/APC, LC/APC, E2000/APC

 

RF Performance
RF bandwidth 5 MHz to 204 MHz
RF output level (2)
47.5 dBmv @ -6 dBm
RF flatness ± 0.75 dB (5 MHz to 204 MHz)
Gain adjustment ~15 ~ 60 dB in 0.5 dB increments (default 42 dB)
RF impedance 75 Ω
RF return loss > 18 dB
Receiver isolation > 65 dB
RF test point relative to RF input port -20 dB ± 1 dB
RF connectors 4 x GSK-type female
RF test points 4 x Mini-SMB
Alarms and laser status  Front-panel LEDs, SNMP Traps

 

Link Performance
CNR (3) > 51 dB
IMD2 (4) > 60 dB
NPR (5) = 25 dB (Dynamic range @ 30 dB)

 

General
Power supply Powered via AIMA3000 backplane
Power consumption < 18 W (without FBC)
< 20 W (with FBC)
Operating temperature  -5 ℃ to +55℃
Storage temperature -25℃ to +70℃
Dimensions (WxDxH) 24.6 x 410 x 152.5 mm
Weight 0.95 kg
Supported network management options PBN’s NMSE or through ASMM’s Web Interface

 

FBC Module
Frequency capture range 5 to 204 MHz
Dynamic range 60 dB
Spectrum Lines 3, including live, max hold and min hold
RBW Up from 30 KHz
VBW Auto adaptable
Vertical Markers 2

Note:

(1) Standard option. Contact a PBN Sales Representative for availability of other options.
(2) Measured in a typical system with -6 dBm optical input, 6% OMI, gain setting adjusted to 50 dB (the stated RF output level does not necessarily apply with other optical input levels). dBuV= 60+dBmV.
(3) Measured @ -6 dBm, 6% OMI, 4 channels
(4) Measured in a typical system with PBN RT5S-D, 4 channels, (11.5 MHz, 26.5 MHz, 45.5 MHz and 58.5 MHz), -6 dBm, 6% OMI. IMD2 is measured at f1 ± f2.
(5) Measured in a typical system with PBN RT5S-D.

A-RRAS-[W]-[X]-[Y]-[Z] Analog Return Receiver – Standard
Options:
W Number of Optical Ports
Q Quad (4)
X FBC Function (1)
M With FBC Management
Y Optical Connector Type
S

F

L

E

SC/APC (2)

FC/APC

LC/APC

E2000/APC

Z Bandwidth
20 5 ~ 204 MHz (Standard)

Note:

(1) Option for FBC Management configurations only, if not used omit X when making an order.
(2) Standard option. Contact a PBN Sales Representative for availability of other options.

Speak to an expert